Dymo P3 Manuel du propriétaire Page 24

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 23
24
DYMO
36
Computer shrouding
1
74
Computer face
sticker
1
37
Screw
ST4.2*20
4
75
Computer circuit
board
1
38
Computer
1
76
Screw
ST2.9*6.5
12
12. TROUBLE SHOOTING GUIDE
Fault Code
Main reason
Solution
E01
The wire from treadmill display to
bottom control board is not
connected
1 Check the connection wire between
computer and control board was well
connected.
2 Ensure the IC on the control board was
well inserted.
3 Abnormal power supply in control board.
Please replace control board.
E02
Protect the exploding
1 Bad contact with motor open circuit.
Please change a new motor or check the
connector.
2 Power tube was puncture. Please
change a new Power tube or control
board.
E05
Over current Protection
1 Overloaded
2 Running board experiencing heavy
resistance and needs to be oiled
3 Damage to motor, replace motor.
E06
Control board self-checking
E08
EEPROM damage
Change the control board